DrywallHannoverOctober 2024

Acoustic ceilings and partitions for studio in Hannover

Recording studio with 58 dB sound insulation, acoustic panels and decoupled drywall construction.

About this project

The drywall project in Hannover demanded specialised fire and sound insulation properties. VL-Innovativbau is certified per DIN 4102 for F90 constructions. We installed double GKF planking 12.5 mm + 25 mm filled with 100 kg/m³ mineral wool. Spring-clip decoupling achieves Rw 58 dB sound insulation — confirmed by measurement protocol. All transitions to ceiling and floor were finished with connection foam and fire-protection sealant. The Q3 finish was applied in 3 layers with sanding in between. Documentation: fire safety proof, sound protocol, material test certificates — all provided for site manager sign-off.

Brief

Operations could not be interrupted during the works — partition walls had to be built in two daily phases.

Solution

Profile pre-assembly in the evening, planking in the morning before opening. Mobile dust lock + HEPA filter. Weekend work for fire-protection details.

Technical data

Fire resistance
F90
Sound insulation
Rw 58 dB
Surface grade
Q3
Certification
DIN 4102
Warranty
5 Jahre
Project duration3 Wochen

Materials & manufacturers

  • Knauf GKB / GKF 12,5 mm
  • CW/UW-Profile 50/75/100
  • Isover Mineralwolle 60-100 mm
  • Akustikplatten OWA
  • Brandschutz-Spachtel F90
  • Federbügel zur Entkoppelung

Related projects