DrywallNienstädtJune 2024

F90 fire-protection walls for commercial building Nienstädt

F90 fire-protection walls for commercial use area, tested per DIN 4102. Including documentation.

About this project

The drywall project in Nienstädt demanded specialised fire and sound insulation properties. VL-Innovativbau is certified per DIN 4102 for F90 constructions. We installed double GKF planking 12.5 mm + 25 mm filled with 100 kg/m³ mineral wool. Spring-clip decoupling achieves Rw 58 dB sound insulation — confirmed by measurement protocol. All transitions to ceiling and floor were finished with connection foam and fire-protection sealant. The Q3 finish was applied in 3 layers with sanding in between. Documentation: fire safety proof, sound protocol, material test certificates — all provided for site manager sign-off.

Brief

Operations could not be interrupted during the works — partition walls had to be built in two daily phases.

Solution

Profile pre-assembly in the evening, planking in the morning before opening. Mobile dust lock + HEPA filter. Weekend work for fire-protection details.

Technical data

Fire resistance
F90
Sound insulation
Rw 58 dB
Surface grade
Q3
Certification
DIN 4102
Warranty
5 Jahre
Project duration3 Wochen

Materials & manufacturers

  • Knauf GKB / GKF 12,5 mm
  • CW/UW-Profile 50/75/100
  • Isover Mineralwolle 60-100 mm
  • Akustikplatten OWA
  • Brandschutz-Spachtel F90
  • Federbügel zur Entkoppelung